Main circuit adopts thyristor 6 phase half-wave control technology, which has stable performance and high reliability. Unique control circuit design is adopted, with CC or CV output, suitable for SAW, MIG/MAG, Flux-cored wire, Carbon arc air gouging and EAW. Voltage fluctuation compensation circuit can effectively compensate the gird voltage fluctuations, strong ability to adopt to the power supply grid. Main AC contractor has no current switch design. It has long service life and slight impact to the electric network. |
Main circuit adopts 3 phase half-controlled bridge, simple circuit and easy maintenance. CC or CV output arc available, suitable for SAW, Carbon arc air gouging and ESW. Main AC contractor has no current switch designed, long service life, small impact on the power grid. |
Magnetic current adjusting means, wide adjustment range, no mechanical noise. Adopt automatic compensation design, can effectively compensate for the fluctuations in the grid voltage to ensure the welding performance. |
Option
Carbon arc air gouging clip |